Data Center Design & Implementation

Planning, power, cooling, racks, cabling and monitoring, delivered as one coordinated build.

Architecture
  1. 01 Site & room planning
  2. 02 Power continuity
  3. 03 Cooling & airflow
  4. 04 Racks & structured cabling
  5. 05 Compute, storage & core network
  6. 06 Monitoring & operations
Infrastructure

The problem

Most server rooms grow by accident. Equipment is added rack by rack, power and cooling are stretched to fit, and cabling becomes impossible to trace. The result is a room that works until it doesn’t: an overloaded circuit, a cooling failure in summer, or a restore that takes days. A designed data center starts from your capacity, availability and growth requirements, then plans every layer to meet them, with documentation your team can operate from.

What you get

  • OutcomePredictable capacityPower and cooling sized to today’s load with documented headroom.
  • OutcomeFewer single points of failureRedundancy where your availability target requires it, not everywhere.
  • OutcomeTraceable infrastructureLabelled cabling, rack elevations and as-built drawings.
  • OutcomeVisibilityEnvironmental and power monitoring with alerts to the right people.
Who it’s for

Who it’s for

CIO, CTO, IT director

A platform that supports growth and new systems without repeated emergency upgrades.

Facilities & operations

Clear power, cooling and space requirements, coordinated with the building.

Procurement

A specification and bill of materials that separates equipment supply from services and support.

Architecture

How the solution is put together

  1. 01

    Site & room planning

    Space, floor loading, access, fire considerations and growth zones.

  2. 02

    Power continuity

    UPS sizing, distribution, generator integration and runtime planning.

  3. 03

    Cooling & airflow

    Cooling capacity, containment and airflow matched to rack density.

  4. 04

    Racks & structured cabling

    Rack layout, copper and fibre backbone, labelling and patching standards.

  5. 05

    Compute, storage & core network

    Servers, storage and backup targets, and the switching and routing that connect them.

  6. 06

    Monitoring & operations

    Environmental, power and system monitoring, alerting and runbooks.

Implementation

From requirements to handover

  1. 01Requirements & capacityLoad, availability target, growth horizon.
  2. 02Site surveyExisting room, building services, constraints.
  3. 03Design & bill of materialsDrawings, specifications and a phased plan for approval.
  4. 04Build & installCoordinated installation with planned maintenance windows.
  5. 05Commission & testFailover, load and alarm tests against acceptance criteria.
  6. 06Handover & supportAs-built documentation, training and agreed support.
Standards & security

Standards & security

Under review

Where you need it, the design can follow the topology and redundancy concepts of TIA-942 and support controls from ISO/IEC 27001, such as physical access, environmental protection and change management. Alignment is not certification: IZONE does not state that it, or any delivered facility, is certified against these standards unless a certificate is published with the project.

Connected technologies

Technologies often used in this solution

  • MikroTik Routers, switches, RouterOS Technology / Brand
  • HPE Enterprise Servers, storage, networking Technology / Brand
  • Dell Technologies Servers, storage, client devices Technology / Brand
  • QNAP NAS & backup storage Technology / Brand
  • Seagate Technology Enterprise & surveillance drives Technology / Brand
Related project

Secure Data Center for a Financial Institution

Modernisation of a financial institution’s data center infrastructure, covering servers, storage and power, using HPE, QNAP and Seagate technologies.

Outcomes under review From the previous website. Figures are withheld until verified.

Read the project
Buyer questions

Frequently asked

Can you work with an existing server room rather than a new build?

Yes. Many projects start with an assessment of the current room: power, cooling, rack layout and cabling. The design then sets out what to keep, upgrade or replace.

Do you supply the equipment as well as the design?

IZONE can design, supply and install. Every proposal states which items are equipment supply, which are services, and what support applies after handover.

How do you handle downtime during migration?

Migration is planned in phases with agreed maintenance windows and rollback steps, so critical services keep running.

What happens after handover?

You receive as-built documentation and operator training. Ongoing support is provided on agreed terms during published working hours.